Cyclic fatigue strength of rotary versus hand instruments in endodontics [Resistencia a la fatiga cíclica de instrumentos rotatorios frente a instrumentos manuales en endodoncia]
DOI:
https://doi.org/10.62574/824qnv32Keywords:
dental materials, smart materials, alloysAbstract
Objective: To analyse the cyclic fatigue strength of rotary versus hand instruments in endodontics. Method: Systematic review of 15 articles. Results and Conclusion: Analysis of the cyclic fatigue resistance of rotary versus hand instruments in endodontics shows that rotary instruments, especially those made of heat-treated nickel-titanium, far outperform hand instruments in terms of durability, flexibility and ability to withstand repetitive deformation under adverse clinical conditions. Advances in design, heat treatment and manufacturing techniques have optimised the performance of rotary instruments, enabling more efficient and safer root canal preparation, even in complex anatomies.
Downloads
References
Moradas Estrada M. Instrumentación rotatoria en endodoncia: ¿qué tipo de lima o procedimiento es el más indicado? Av Odontoestomatol [Internet]. 2017;33(4): 151-160.
Geraldes Pappen Fernanda, Aguirre Guillermo Mauricio, Rivas Gutiérrez José Carlos, Nogueira Indri, Bonetti-Filho Idomeo, García Puente Carlos et al. Efectividad de las técnicas rotatoria y oscilatoria en la preparación de conductos radiculares de conformación ovalada. Acta odontol. venez [Internet]. 2007;45(4): 528-533.
Castelló-Escrivá R, Alegre-Domingo T, Faus-Matoses V, Román-Richon S, Faus-Llácer VJ. In vitro comparison of cyclic fatigue resistance of ProTaper, WaveOne, and Twisted Files. J Endod. 2012;38(11):1521-1524. doi:10.1016/j.joen.2012.07.010
Keskin NB, Inan U. Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods. Microsc Res Tech. 2019;82(10):1642-1648. doi:10.1002/jemt.23330
Pedullà E, Benites A, La Rosa GM, et al. Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and/or Sterilization. J Endod. 2018;44(4):648-653. doi:10.1016/j.joen.2017.12.011
Kamali SG, Turkaydin D. Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use. Niger J Clin Pract. 2021;24(2):247-253. doi:10.4103/njcp.njcp_166_20
Ersoy I, Kol E, Uygun AD, Tanriver M, Seckin F. Comparison of cyclic fatigue resistance between different NiTi instruments with 4% taper. Microsc Res Tech. 2016;79(5):345-348. doi:10.1002/jemt.22636
Bulem ÜK, Kececi AD, Guldas HE. Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization. J Appl Oral Sci. 2013;21(6):505-510. doi:10.1590/1679-775720130083
Karataşlıoglu E, Aydın U, Yıldırım C. Cyclic Fatigue Resistance of Novel Rotary Files Manufactured from Different Thermal Treated Nickel-Titanium Wires in Artificial Canals. Niger J Clin Pract. 2018;21(2):231-235. doi:10.4103/njcp.njcp_296_16
Pedullà E, Corsentino G, Ambu E, et al. Influence of continuous rotation or reciprocation of Optimum Torque Reverse motion on cyclic fatigue resistance of nickel-titanium rotary instruments. Int Endod J. 2018;51(5):522-528. doi:10.1111/iej.12769
Uslu G, Özyürek T, Gündoğar M, Yılmaz K. Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature. J Dent Res Dent Clin Dent Prospects. 2018;12(4):283-287. doi:10.15171/joddd.2018.044
Gündoğar M, Özyürek T, Yılmaz K, Uslu G. Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne Gold, and Twisted File Adaptive rotary files under different temperatures and ambient conditions. J Dent Res Dent Clin Dent Prospects. 2019;13(3):166-171. doi:10.15171/joddd.2019.026
Aminsobhani M, Meraji N, Sadri E. Comparison of Cyclic Fatigue Resistance of Five Nickel Titanium Rotary File Systems with Different Manufacturing Techniques. J Dent (Tehran). 2015;12(9):636-646.
Kimura S, Ebihara A, Maki K, et al. Phase transformation behavior and mechanical properties of HyFlex EDM nickel-titanium endodontic rotary instrument: Evaluation at body temperature. J Dent Sci. 2024;19(2):929-936. doi:10.1016/j.jds.2023.07.039
Khandagale PD, Shetty PP, Makandar SD, et al. Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study. Int J Dent. 2021;2021:7402658. Published 2021 Jul 29. doi:10.1155/2021/7402658
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Copyright (c) 2024 By the authors. This article is open access and distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) licence (https://creativecommons.org/licenses/by-nc-sa/4.0/).
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
CC BY-NC-SA : Esta licencia permite a los reutilizadores distribuir, remezclar, adaptar y construir sobre el material en cualquier medio o formato solo con fines no comerciales, y solo siempre y cuando se dé la atribución al creador. Si remezcla, adapta o construye sobre el material, debe licenciar el material modificado bajo términos idénticos.