Cyclic fatigue strength of rotary versus hand instruments in endodontics [Resistencia a la fatiga cíclica de instrumentos rotatorios frente a instrumentos manuales en endodoncia]

Authors

DOI:

https://doi.org/10.62574/824qnv32

Keywords:

dental materials, smart materials, alloys

Abstract

Objective: To analyse the cyclic fatigue strength of rotary versus hand instruments in endodontics. Method: Systematic review of 15 articles. Results and Conclusion: Analysis of the cyclic fatigue resistance of rotary versus hand instruments in endodontics shows that rotary instruments, especially those made of heat-treated nickel-titanium, far outperform hand instruments in terms of durability, flexibility and ability to withstand repetitive deformation under adverse clinical conditions. Advances in design, heat treatment and manufacturing techniques have optimised the performance of rotary instruments, enabling more efficient and safer root canal preparation, even in complex anatomies.

Downloads

Download data is not yet available.

References

Moradas Estrada M. Instrumentación rotatoria en endodoncia: ¿qué tipo de lima o procedimiento es el más indicado? Av Odontoestomatol [Internet]. 2017;33(4): 151-160.

Geraldes Pappen Fernanda, Aguirre Guillermo Mauricio, Rivas Gutiérrez José Carlos, Nogueira Indri, Bonetti-Filho Idomeo, García Puente Carlos et al. Efectividad de las técnicas rotatoria y oscilatoria en la preparación de conductos radiculares de conformación ovalada. Acta odontol. venez [Internet]. 2007;45(4): 528-533.

Castelló-Escrivá R, Alegre-Domingo T, Faus-Matoses V, Román-Richon S, Faus-Llácer VJ. In vitro comparison of cyclic fatigue resistance of ProTaper, WaveOne, and Twisted Files. J Endod. 2012;38(11):1521-1524. doi:10.1016/j.joen.2012.07.010

Keskin NB, Inan U. Cyclic fatigue resistance of rotary NiTi instruments produced with four different manufacturing methods. Microsc Res Tech. 2019;82(10):1642-1648. doi:10.1002/jemt.23330

Pedullà E, Benites A, La Rosa GM, et al. Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Instruments after Immersion in Sodium Hypochlorite and/or Sterilization. J Endod. 2018;44(4):648-653. doi:10.1016/j.joen.2017.12.011

Kamali SG, Turkaydin D. Cyclic fatigue resistance and shaping ability of heat-treated nickel-titanium instruments after repeated use. Niger J Clin Pract. 2021;24(2):247-253. doi:10.4103/njcp.njcp_166_20

Ersoy I, Kol E, Uygun AD, Tanriver M, Seckin F. Comparison of cyclic fatigue resistance between different NiTi instruments with 4% taper. Microsc Res Tech. 2016;79(5):345-348. doi:10.1002/jemt.22636

Bulem ÜK, Kececi AD, Guldas HE. Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization. J Appl Oral Sci. 2013;21(6):505-510. doi:10.1590/1679-775720130083

Karataşlıoglu E, Aydın U, Yıldırım C. Cyclic Fatigue Resistance of Novel Rotary Files Manufactured from Different Thermal Treated Nickel-Titanium Wires in Artificial Canals. Niger J Clin Pract. 2018;21(2):231-235. doi:10.4103/njcp.njcp_296_16

Pedullà E, Corsentino G, Ambu E, et al. Influence of continuous rotation or reciprocation of Optimum Torque Reverse motion on cyclic fatigue resistance of nickel-titanium rotary instruments. Int Endod J. 2018;51(5):522-528. doi:10.1111/iej.12769

Uslu G, Özyürek T, Gündoğar M, Yılmaz K. Cyclic fatigue resistance of 2Shape, Twisted File and EndoSequence Xpress nickel-titanium rotary files at intracanal temperature. J Dent Res Dent Clin Dent Prospects. 2018;12(4):283-287. doi:10.15171/joddd.2018.044

Gündoğar M, Özyürek T, Yılmaz K, Uslu G. Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne Gold, and Twisted File Adaptive rotary files under different temperatures and ambient conditions. J Dent Res Dent Clin Dent Prospects. 2019;13(3):166-171. doi:10.15171/joddd.2019.026

Aminsobhani M, Meraji N, Sadri E. Comparison of Cyclic Fatigue Resistance of Five Nickel Titanium Rotary File Systems with Different Manufacturing Techniques. J Dent (Tehran). 2015;12(9):636-646.

Kimura S, Ebihara A, Maki K, et al. Phase transformation behavior and mechanical properties of HyFlex EDM nickel-titanium endodontic rotary instrument: Evaluation at body temperature. J Dent Sci. 2024;19(2):929-936. doi:10.1016/j.jds.2023.07.039

Khandagale PD, Shetty PP, Makandar SD, et al. Evaluation of Cyclic Fatigue of Hyflex EDM, Twisted Files, and ProTaper Gold Manufactured with Different Processes: An In Vitro Study. Int J Dent. 2021;2021:7402658. Published 2021 Jul 29. doi:10.1155/2021/7402658

Published

2024-11-06

How to Cite

1.
Corrales-Valles LP, Velastegui-Valenzuela SM, Ibarra-Ramírez MB. Cyclic fatigue strength of rotary versus hand instruments in endodontics [Resistencia a la fatiga cíclica de instrumentos rotatorios frente a instrumentos manuales en endodoncia]. SRS [Internet]. 2024 Nov. 6 [cited 2024 Dec. 26];3(especial odontologia):245-51. Available from: https://revistasinstitutoperspectivasglobales.org/index.php/sanitas/article/view/272

Similar Articles

1-10 of 45

You may also start an advanced similarity search for this article.