Post-orthodontic stability and relapse: factors and retention protocols, a systematic review
DOI:
https://doi.org/10.62574/b8wh2d52Keywords:
orthodontic retainers, recurrence, orthodontics, correctiveAbstract
Objective: to analyze the factors influencing relapse after orthodontic treatment and the efficacy of retention protocols. Methods: narrative-synthesis systematic review of literature indexed in PubMed (2020 to 2025), using descriptors on relapse, orthodontic retention, fixed and removable retainers and long-term stability; 15 studies were selected and grouped into three themes. Results: five studies synthesized the evidence on retention and relapse, six compared fixed and removable retainers, and four analyzed long-term stability factors and clinical protocols. Conclusion: relapse is multifactorial and no retainer fully prevents it; prolonged retention, case-based appliance selection and patient follow-up are the basis of stability.
Downloads
References
Millett D. The rationale for orthodontic retention: putting the pieces of the puzzle together. Br Dent J. 2021;230(11):739-49.
Martin C, Littlewood SJ, Millett DT, Doubleday B, Bearn D, Worthington HV, et al. Retention procedures for stabilising tooth position after treatment with orthodontic braces. Cochrane Database Syst Rev. 2023;5(5):CD002283.
Kalemaj Z, et al. Which orthodontic retainer provides the best stabilization? Systematic review and network meta-analysis. Eur J Orthod. 2021;43(2):164-73. (completar autores)
Perkovic V, et al. Association between arch width changes and long-term stability 20 years after orthodontic treatment. Angle Orthod. 2023;93(3):261-8. (completar autores)
Aras I, Griffith R, Trouten J, Alexander M, Akyalcin S. Long-term relapse of anterior teeth in orthodontic patients treated with and without premolar extractions using a 3-dimensional surface mesh analysis. Am J Orthod Dentofacial Orthop. 2025;168(2):232-42.
Ali US, Zafar K, Sukhia RH, Fida M, Ahmed A. Effect of bonded and removable retainers on occlusal settling after orthodontic treatment: a systematic review and meta-analysis. Dent Med Probl. 2023;60(2):327-34.
Alam MK, Alayyash A. Management strategies for open bite relapse: a systematic review and meta-analysis. Cureus. 2024;16(3):e56285.
Chagas AS, et al. Level of satisfaction in the use of the wraparound Hawley and thermoplastic maxillary retainers. Angle Orthod. 2020;90(1):63-9. (completar autores)
Ashari A, Xian L, Mohamed AMFS, Wahab RMA, Kit YC, Tata MD, et al. One-year comparative assessment of retention of arch width increases between modified vacuum-formed and Hawley retainers. Angle Orthod. 2022;92(2):197-204.
Firlej M, et al. Mechanical properties of 3D printed orthodontic retainers. Int J Environ Res Public Health. 2022;19(9):5775. (completar autores)
Gera A, et al. Stability, survival, and patient satisfaction with CAD/CAM versus conventional multistranded fixed retainers. Eur J Orthod. 2023;45(1):58-67. (completar autores)
Pullisaar H, et al. Stability, survival, patient satisfaction, and cost-minimization of CAD/CAM versus conventional multistranded fixed retainers. Eur J Orthod. 2024;46(2):cjae006. (completar autores)
Kanizaj Ugrin S, et al. Stability, survival and costs of vacuum-formed retainers versus bonded lingual braided rectangular and multistranded round wire retainers. BMC Oral Health. 2025;25:1782. (completar autores)
Alayyash A. Effectiveness of different retention protocols in preventing posttreatment relapse after comprehensive orthodontic treatment. J Pharm Bioallied Sci. 2024;16(Suppl 1):S148-51.
Mohanty B, Ravuri P, Kubavat AK, Kauser A, Bansilal Wagh S, Varma Datla PK, et al. Evaluation of orthodontic retention protocols and their impact on treatment stability: insights from a tertiary care study. J Pharm Bioallied Sci. 2024;16(Suppl 3):S1997-9.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Por los autores

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Esta obra está bajo una licencia internacional Creative Commons Atribución-NoComercial-CompartirIgual 4.0.
CC BY-NC-SA : Esta licencia permite a los reutilizadores distribuir, remezclar, adaptar y construir sobre el material en cualquier medio o formato solo con fines no comerciales, y solo siempre y cuando se dé la atribución al creador. Si remezcla, adapta o construye sobre el material, debe licenciar el material modificado bajo términos idénticos.





